Title: 40-6 Flap System step 1-4 New Actuator
Installation of clamps for the multiconductor wire. Installed Pins for the CPC connector (female on the actuator side. Original VANS documentation attached (unfortunately colors don't exactly match). Added the documentation from the manufacturer of the actuator (PH Aviation Services, Inc) CPC mapping of the wires as follows (only 5 wires are active, one is not active. Slot nr 4 NOT USED) 1 RED AWG 18 POWER (EXTRACT FLAP) 2 Red AWG20 POT WIPER (SIGNAL) 3 BLACK AWG18 POWER (RETRACT FLAP) 5 Black AWG20 NOT USED BUT INSTALLED 6 YELLOW AWG20 POT 5 SCVD (REFERENCE) 7 WHITE AWG20 POT GND (REFERENCE) Manual recommend 10 AMP Breaker on power lines (Extract / retract)


NOTE: This information is strictly used for the EAA Builders Log project within the EAA organization.     -     Policy     -     © Copyright 2024 Brevard Web Pro, Inc.