Title: Avionics and Electrical
Assembled and completed connectors GDU P4601 and P4602 except for connecting the ground shields to the connector shell. Documented the CAN bus termination splice on the schematic and in the wire list. Connected Power 1 and then Power 2 to a battery to see the GDU 460 power up for the very first time and verify both power connections. Explored and decided on an option for the cable service loop for the GDU. Decided on a similar loop that is ~19 inches long for the G5 and will wire it next. Printed all the heat shrink tubing labels for the G5, GSU, GAD 29 and the CO detector. I didn't log the hours, but spent another 3 hours in the garage organizing things so I can get rid of some file cabinets and have room for an engine crate.